Aftercoolers
- Sizing
- Approach Temperature
- Specifications
- Dimensional Drawings
- Price Van Air AC Series Aftercoolers
- AC Series Aftercoolers Brochure (pdf format)
eCompressedair sells Van Air AC aftercoolers as kits. The aftercooler kit includes: aftercooler, flex hose, separator, and drain.
The AC Series aftercooler should be installed directly after the air compressor.
Aftercoolers comes with:
- Aftercooler
- Flex hose
- Separator
- Automatic drain
- Maximum operating pressure: 250 psig
- Maximum operating temperature: 350°F
- Pressure drop less than 3 psi at 80-125 psig.
Capacities based on operating pressures of 80 psig to 125 psig. For capacities out of this range call 704-846-2004.
Sizing
- Determine inlet temperature to aftercooler
- Determine desired outlet temperature. (Aftercooler outlet temperature = ambient temperature + approach)
- Determine needed approach. (Approach = desired outlet temperature - ambient temperature)
- Find flow (SCFM) under column of correct inlet and approach temperature and read left for model number.
Approach Temperatures
To use the approach temperature tables you need to decide if you want a 5, 10, 15 or 20 degree approach temperature. Second you need to know your flow rate (SCFM). Third you need to know the temperature of your compressed air as it leaves the air compressor (discharge temperature). For example:
- Air Compressor produces 250 SCFM
- Compressed air discharge temperature 250 F
- And we want a 10 F approach temperature
The correct unit for these conditions is a AC-140
Approach temperature is the difference between the ambient temperature and the compressed air temperature. So, going back to our example. If the ambient temperature is 75°F and the approach temperature is 10°F than the compressed air will be approximately 85°F at the outlet of the air receiver. The compressed air enters 250°F and leaves 85°F. It is critical to have a separator and drain installed at the outlet of the aftercooler to collect all the moiture that drops out as the air is cooled.
| | 150 F Inlet Approach | 200 F Inlet Approach | 250 F Inlet Approach |
| Model | 5 | 10 | 15 | 20 | 5 | 10 | 15 | 20 | 5 | 10 | 15 | 20 |
| AC-10 | 17 | 35 | 35 | 35 | 11 | 22 | 35 | 35 | 8 | 16 | 20 | 35 |
| AC-20 | 29 | 43 | 43 | 43 | 17 | 36 | 43 | 43 | 12 | 27 | 35 | 43 |
| AC-30 | 43 | 72 | 72 | 72 | 28 | 50 | 70 | 72 | 22 | 35 | 50 | 70 |
| AC-40 | 95 | 125 | 125 | 125 | 66 | 111 | 125 | 125 | 52 | 88 | 100 | 125 |
| AC-60 | 34 | 58 | 79 | 99 | 25 | 43 | 59 | 74 | 21 | 36 | 50 | 62 |
| AC-80 | 50 | 87 | 119 | 150 | 40 | 69 | 94 | 117 | 34 | 59 | 80 | 100 |
| AC-100 | 81 | 138 | 190 | 235 | 61 | 105 | 142 | 177 | 51 | 87 | 120 | 150 |
| AC-110 | 92 | 160 | 220 | 270 | 73 | 125 | 172 | 215 | 63 | 110 | 150 | 187 |
| AC-120 | 160 | 275 | 380 | 425 | 120 | 207 | 285 | 355 | 100 | 175 | 240 | 300 |
| AC-130 | 184 | 318 | 440 | 480 | 145 | 250 | 345 | 430 | 125 | 217 | 300 | 375 |
| AC-140 | 210 | 384 | 520 | 605 | 175 | 375 | 430 | 500 | 160 | 300 | 400 | 464 |
| AC-150 | 355 | 650 | 890 | 1025 | 308 | 560 | 760 | 880 | 290 | 545 | 725 | 840 |
| AC-160 | 480 | 871 | 1178 | 1360 | 415 | 754 | 1020 | 1180 | 390 | 712 | 950 | 1100 |
| AC-170 | 600 | 1090 | 1475 | 1710 | 520 | 950 | 1290 | 1460 | 490 | 900 | 1200 | 1380 |
| AC-180 | 790 | 1440 | 1950 | 2260 | 710 | 1290 | 1720 | 1950 | 660 | 1200 | 1600 | 1860 |
| AC-190 | 980 | 1790 | 2420 | 2800 | 870 | 1580 | 2140 | 2460 | 820 | 1490 | 2000 | 2300 |
| AC-200 | 1220 | 2200 | 3000 | 3470 | 1090 | 1980 | 2680 | 3100 | 1035 | 1880 | 2500 | 2870 |
| AC-210 | 1450 | 2650 | 3580 | 4120 | 1295 | 2360 | 3200 | 3710 | 1243 | 2260 | 3000 | 3450 |
| AC-220 | 1680 | 3064 | 4140 | 4800 | 1530 | 2785 | 3760 | 4320 | 1460 | 2660 | 3500 | 4015 |
| | 300 F Inlet Approach | 350 F Inlet Approach |
| Model | 5 | 10 | 15 | 20 | 5 | 10 | 15 | 20 |
| AC-10 | 6 | 12 | 19 | 26 | 5 | 10 | 15 | 21 |
| AC-20 | 10 | 20 | 31 | 42 | 8 | 16 | 26 | 35 |
| AC-30 | 18 | 32 | 45 | 57 | 15 | 28 | 39 | 50 |
| AC-40 | 44 | 74 | 100 | 125 | 38 | 64 | 86 | 108 |
| AC-60 | 18 | 31 | 42 | 52 | 16 | 27 | 38 | 47 |
| AC-80 | 30 | 52 | 71 | 89 | 28 | 47 | 65 | 82 |
| AC-100 | 43 | 75 | 102 | 127 | 40 | 69 | 94 | 116 |
| AC-110 | 55 | 95 | 130 | 160 | 50 | 86 | 120 | 148 |
| AC-120 | 84 | 145 | 204 | 250 | 78 | 135 | 185 | 231 |
| AC-130 | 110 | 190 | 257 | 320 | 100 | 175 | 240 | 300 |
| AC-140 | 135 | 250 | 340 | 396 | 125 | 235 | 305 | 355 |
| AC-150 | 245 | 450 | 605 | 701 | 225 | 410 | 540 | 625 |
| AC-160 | 320 | 588 | 785 | 910 | 280 | 520 | 690 | 780 |
| AC-170 | 405 | 735 | 980 | 1130 | 355 | 650 | 865 | 990 |
| AC-180 | 530 | 965 | 1290 | 1480 | 460 | 840 | 1135 | 1300 |
| AC-190 | 660 | 1210 | 1595 | 1840 | 572 | 1040 | 1400 | 1610 |
| AC-200 | 784 | 1426 | 1980 | 2270 | 705 | 1290 | 1725 | 1980 |
| AC-210 | 985 | 1794 | 2360 | 2715 | 840 | 1530 | 2040 | 2350 |
| AC-220 | 1150 | 2090 | 2760 | 3200 | 950 | 1740 | 2350 | 2700 |
Specifications by Model
eCompressedair supplies the aftercoolers as a kit including the following components.
- Aftercooler
- Flex hose
- Moisture separator
- Automatic float drain
Models AC-10 through AC-40
- Ambient air flow: horizontal or vertical
- Floor or suspended mounting
- Steel cabinet with baked enamel finish
- Copper tubed, aluminum finned core
- Zinc chromate-plated steel fan guard
- Open vented motor with thermal overload
- NEMA frame: custom
Models AC-60 through AC-130
- Ambient air flow: Horizontal
- Floor or suspended mounting
- Galvanized steel cabinet
- Copper tube core with aluminum fins
- Heavy gauge aluminum fan with steel hub
- Open vented motor
- NEMA frame: custom on 115-1-60 ODP models, NEMA 48 on others
- Thermal overload on 115-1-60 ODP models only
Models AC-140 through AC-220
- Ambient Air flow: vertical
- Steel legs with baked enamel finish
- Aluminum core
- Aluminum fan hub with polypropylene blades
- Painted steel fan shroud
- Steel fan guard with baked enamel finish
- TEFC motor
- NEMA Frame:
- 56C on models AC-140 and AC-150
- 145TC on model AC-160
- 182TC or 184TC on model AC-170
- 184TC on model AC-180
- 213TC on models AC-190 and AC-200
- 215TC on models AC-210 and AC-220
Options & Accessories
- TEFC motor on models AC-60 through Ac-130
- Air motors on models AC-140 through AC-220
- Low temperature kits: Shut off fan(s) at 35°F outlet temperature
- FP-3 for AC-60 through AC-130
- FP-4 for AC-140 through AC-220
Dimensions and Specs by Model
Match the letters in the drawings with the letters in the table heading to better understand dimensions.
| Model | Height (in.) A | Width (in.) B | Depth (in.) C | Height to Inlet (in.) D | Height to Outlet (in.) E | Conn. (NPT) | Motor HP | Weight (lbs.) |
| AC-10 | 22 | 20 | 12 | 8 | 8 | 1/2 | 1/12 | 25 |
| AC-20 | 22 | 20 | 12 | 8 | 8 | 1/2 | 1/12 | 25 |
| AC-30 | 42 | 26 | 15 | 42 | 19 | 1 | 1/12 | 61 |
| AC-40 | 42 | 26 | 15 | 42 | 19 | 1 1/2 | 1/12 | 67 |
| AC-60 | 51 | 31 | 18 | 51 | 22 | 1 | 1/4 | 110 |
| AC-80 | 51 | 31 | 18 | 51 | 22 | 1 1/2 | 1/4 | 120 |
| AC-100 | 51 | 44 | 18 | 51 | 22 | 1 1/2 | 1/4 | 140 |
| AC-110 | 51 | 44 | 18 | 51 | 22 | 1 1/2 | 1/4 | 140 |
| AC-120 | 51 | 48 | 18 | 54 | 22 | 2 | 1/4 (2) | 200 |
| AC-130 | 60 | 52 | 19 | 60 | 22 | 2 | 1/4 (2) | 300 |
| AC-140 | 34 | 26 | 19 | 32 | 32 | 2 | 1 | 120 |
| AC-150 | 34 | 34 | 24 | 32 | 32 | 2 | 1.5 | 170 |
| AC-160 | 36 | 41 | 28 | 33 | 33 | 3 | 1.5 | 330 |
| AC-170 | 36 | 44 | 28 | 33 | 33 | 3 | 5 or 3 | 450 |
| AC-180 | 36 | 44 | 36 | 33 | 33 | 3 | 5 | 515 |
| AC-190 | 36 | 54 | 39 | 33 | 33 | 3 | 7.5 | 600 |
| AC-200 | 36 | 52 | 45 | 33 | 33 | 4 | 7.5 | 625 |
| AC-210 | 36 | 54 | 54 | 33 | 33 | 4 | 10 | 645 |
| AC-220 | 36 | 54 | 58 | 33 | 33 | 4 | 10 | 750 |
See table above to match letters with dimensions by model.
Models AC-10 & AC-20

|
Models AC-30 & AC-40

|
Models AC-60 through AC-130

|
Models AC-140 and Larger

|
Price Van Air AC Series Aftercoolers
Click on a model for pricing and specifications.
AC-10 Van Air Aftercooler
AC-20 Van Air Aftercooler
AC-30 Van Air Aftercooler
AC-40 Van Air Aftercooler
AC-60 Van Air Aftercooler
AC-80 Van Air Aftercooler
AC-100 Van Air Aftercooler
AC-110 Van Air Aftercooler
AC-120 Van Air Aftercooler
AC-130 Van Air Aftercooler
AC-140 Van Air Aftercooler
AC-150 Van Air Aftercooler
AC-160 Van Air Aftercooler
AC-170 Van Air Aftercooler
AC-180 Van Air Aftercooler
AC-190 Van Air Aftercooler
AC-200 Van Air Aftercooler
AC-210 Van Air Aftercooler
AC-220 Van Air Aftercooler
|
|
|