Deltech Del-Monox G Series Breathing Air Systems
Deltech is updating the G Series. Call for prices or consider the Hankison Catalite system.
G Series Models 8 to 125 SCFM
How Deltech G Series Breathing Air Systems Work
How To Size a G Series Breathing Air Systems
Specifications
Specifcations and Pricing
Delmonox Replacement Filter Elements for all models
Inlet air enters a three-in-
one prefilter E where solid
particles, liquid oil and water are
removed. The prefilter changes
color to signal element replacement.
An automatic drain D continually
discharges the separated contaminants.
How G Series Breathing Air Units Work
Filtered air enters one of two
desiccant towers via a four-way
valve G. The twin desiccant towers
remove water vapor. Calibrated
color change strips I indicate relative
humidity and monitor dryer
performance. An electric timer
(110V/75W NEMA Type I) switches
air flow from vessel A to vessel B on
a timed cycle. A small portion of the
dried air (purge air) is used to
regenerate the offstream vessel.
A catalyst C converts carbon
monoxide to carbon dioxide. (A
carbon monoxide monitor and
alarm are available as an option.) An
activated charcoal filter F removes
objectionable tastes and odors. An
afterfilter removes any remaining
particulates. Grade D breathing air is
then supplied to the system.
Product Options:
- Carbon monoxide monitor
- 12VDC Control
- Cart-mounted
- Manufactured to meet NEMA 7 (Class I, Division II, Group D) standards
- High-efficiency prefilter for use with oil-flooded rotary screw compressors
- Electronic automatic drain valve
Sizing Example
In a sandblasting operation, three
workers require 6 scfm each for their
Type CE respirators. The air system
pressure is 100 psig.
The maximum required breathing air
flow rate is 3 x 6 or 18 scfm. From the
Model Selection Chart, using 100 psig
operating pressure as a guide, select a
purifier with an outlet flow that equals
or exceeds 18 scfm. Select model 3H10.
Additional air must be supplied at the
purifier inlet for operation of the dryer.
To estimate the required inlet air flow,
divide the maximum outlet air flow by
0.75. In this example, the required inlet
flow is 24 scfm.
Model Selection Chart
|
Modela
|
Inlet Air Pressure (psig)
|
|
80
|
90
|
100
|
110
|
125
|
150
|
|
Maximum Outlet air Flow (scfm)b
|
| 3F10 | 10 | 11 | 12 | 13 | 14 | 17 |
| 3H10 | 15 | 16 | 18 | 19 | 22 | 26 |
| 3K11 | 20 | 22 | 24 | 26 | 29 | 34 |
| 3L11 | 26 | 29 | 32 | 34 | 39 | 46 |
| 5N12 | 40 | 44 | 48 | 52 | 58 | 68 |
| 5R12 | 66 | 73 | 80 | 86 | 97 | 114 |
| 5S13 | 86 | 95 | 104 | 112 | 126 | 149 | | 5W13 | 105 | 117 | 128 | 138 | 156 | 183 |
a Including equivalent portable models with suffix C.
bBased on saturated 100° F inlet air, 100° F ambient air. Capacity will be
reduced with saturated inlet air at higher temperatures.
Maximum recommended inlet air temperature, 120° F; minimum, 65° F.
Maximum operating pressure, 150 psig; minimum, 75 psig.
Specifications
|
Standard System
|
|
Modela
|
Height (in.)
|
Width (in.)
|
Depth (in.)
|
Weight (lbs.)
|
| 3F10 | 38.5 | 31.5 | 12.75 | 175 |
| 3H10 | 38.5 | 33.5 | 14.5 | 205 |
| 3K11 | 44.5 | 33.5 | 14.5 | 230 |
| 3L11 | 66.5 | 38.5 | 36.0 | 305 |
| 5N12 | 66.5 | 42.5 | 36.0 | 425 |
| 5R12 | 66.5 | 47.5 | 36.0 | 465 |
| 5S13 | 72.5 | 50.75 | 36.0 | 585 |
| 5W13 | 72.5 | 50.75 | 36.0 | 665 |
aModels 1C10 through 3K11 are designed for wall mounting; larger models are furnished with floor stands.
|
Portable Systems
|
|
Modela
|
Height (in.)
|
Width (in.)
|
Depth (in.)
|
Weight (lbs.)
|
| 3F10C | 48.0 | 25.0 | 20.0 | 210 |
| 3H10C | 48.0 | 27.5 | 22.0 | 240 |
| 3K11C | 48.0 | 27.5 | 22.0 | 270 |
| 3L11C | 48.0 | 27.5 | 25.0 | 350 |
| 5N12C | 48.0 | 27.5 | 25.0 | 500 |
| 5R12C | 48.0 | 33.0 | 28.0 | 540 |
| 5S13Ca | 65.0 | 58.0 | 42.0 | 735 |
| 5W13Ca | 75.0 | 68.0 | 42.0 | 795 |
Air Connectionsa
(inches NPT)
|
|
Model
|
In
|
Out
|
| 3F10 | 1 | 3/4 |
| 3H10 | 1 | 3/4 |
| 3K11 | 1 | 3/4 |
| 3L11 | 1 | 1 1/4 |
| 5N12 | 1 1/2 | 1 1/4 |
| 5R12 | 1 1/2 | 1 1/4 |
| 5S13 | 1 1/2 | 1 1/4 |
| 5W13 | 1 1/2 | 1 1/2 |
aMounted on 4-wheel carts. All others are mounted on
2- wheel carts.
Pricing and Specifications
Click on a model number for detailed product specifications and pricing.
Wall Mount Units
Deltech Model 3F10 (12 SCFM)
Deltech Model 3H10 (18 SCFM)
Deltech Model 3K11 (24 SCFM)
Deltech Model 3L11 (32 SCFM)
Deltech Model 5N12 (48 SCFM)
Deltech Model 5R12 (80 SCFM)
Deltech Model 5S13 (104 SCFM)
Deltech Model 5W13 (128 SCFM)
Cart Mounted Models
Deltech Model 3F10C (12 SCFM)
Deltech Model 3H10C (18 SCFM)
Deltech Model 3K11C (24 SCFM)
Deltech Model 3L11C (32 SCFM)
Deltech Model 5N12C (48 SCFM)
Deltech Model 5R12C (80 SCFM)
Deltech Model 5S13C (104 SCFM)
Deltech Model 5W13C (128 SCFM)
|
|
|