ecompressedair toll-free: 1-866-650-1937 ph: 704-846-2004 fax: 704-847-0522 email: sales@ecompressedair.com 
Corporate HQ: 7255 East 46th Street, Tulsa, OK 74145 
Sales office: 2201 Crown Point Executive Dr., Suite A, Charlotte, NC 28227 
Search:       STORE   RFQ   SITE MAP   LIBRARY   CONTACT   LOG IN

Refrigerated Compressed Air Dryers

RD10 to RD40
RD 10 to RD40 Refrigerated Dryers
RD60 and larger refrigerated compressed air dryers
RD60 and larger dryers look similar to the unit above.
  1. RD Series Refrigerated Dryers Specifications
  2. RD Series Refrigerated Dryer Filters
  3. Size RD Series Refrigerated Dryer (Sizing Tool)
eCompressedair offers Van Air's RD Series refrigerated dryers. Models to 500 SCFM are available to purchase online for help with larger units contact us.

Our refrigerated air dryers remove moisture from indoor air lines and reduce maintenance costs associated with air line contaminants. Backed by 50 years of expertise, Van Air’s refrigerated compressed air dryers RD Series offers these advantages and features:
  • 35-38°F dew point
  • Shell and tube heat exchangers for maximum performance and low pressure drop
  • No heat exchanger freeze-ups with low loads
  • 160°F maximum inlet temperature
  • CFC-Free R134A refrigerant
  • Non-cycling refrigerant compressors
  • Refrigerant analyzer gauge
  • Compressor run light
  • Built in drain valve (mechanical on RD-10 to RD-30 and electronic on all other units

Effective Moisture Removal for Indoor Air Systems

For indoor air line protection, RD Series refrigerated dryers keep your pneumatic equipment running at peak efficiency with a constant 35°F-38°F dew point.

Low-Load Protection

A capacity control valve allows the dryer to operate efficiently at low loads by preventing heat exchanger freeze-ups. It also keeps the dew point steady when the flow changes.

Specifications

Click on a model number for pricing and more information.
Model   Standard Capacity Height Width Length In/Out (NPT) Comp. (HP) Comp. (KW) Weight (lbs) Voltage
RD-10 10 SCFM 14 in. 15 in. 18 in. 1/2 in. NPT 1/6 HP .29 KW 69 lbs 120 VAC
RD-20 20 SCFM 14 in. 15 in. 18 in. 1/2 in. NPT 1/5 HP .36 KW 78 lbs 120 VAC
RD-30 30 SCFM 23 in. 14 in. 34 in. 1/2 in. NPT 1/4 HP .46 KW 140 lbs 120 VAC
RD-40 40 SCFM 23 in. 14 in. 34 in. 1/2 in. NPT 1/3 HP .58 KW 160 lbs 120 VAC standard
230 VAC option
RD-60 60 SCFM 23 in. 14 in. 34 in. 1 in. NPT 1/2 HP .86 KW 176 lbs 120 VAC standard
230 VAC option
RD-80 80 SCFM 32 in. 20 in. 35 in. 1 in. NPT 1/2 HP .86 KW 200 lbs 120 VAC standard
230 VAC option
RD-100 100 SCFM 32 in. 20 in. 35 in. 1 in. NPT 3/4 HP 1.2 KW 256 lbs 120 VAC standard
230 VAC option
RD-130 130 SCFM 32 in. 20 in. 35 in. 1 1/2 in. NPT 3/4 HP 1.2 KW 256 lbs 120 VAC standard
230 VAC option
RD-150 150 SCFM 32 in. 20 in. 35 in. 1 1/2 in. NPT 3/4 HP 1.2 KW 270 lbs 120 VAC standard
230 VAC option
RD-220 220 SCFM 38 in. 22 in. 47 in. 2 in. NPT 1 HP 1.75 KW 390 lbs 230 VAC standard
460-3 option
RD-250 250 SCFM 38 in. 22 in. 47 in. 2 in. NPT 1 ½ HP 2.63 KW 418 lbs 230 VAC standard
460-3 option
RD-330 330 SCFM 52 in. 29 in. 55 in. 2 in. NPT 1 ½ HP 2.63 KW 700 lbs 230 VAC standard
460-3 option
RD-400 400 SCFM 52 in. 29 in. 55 in. 2 ½ in. NPT 2 HP 3.5 KW 925 lbs 460-3 Phase
RD-500 500 SCFM 52 in. 29 in. 55 in. 2 ½ in. NPT 3 HP 5.25 KW 968 lbs 460-3 Phase

Refrigerated Dryer Sizing

If operating conditions vary from the standard of 100 PSIG, 100°F inlet temperature, and 100°F ambient, use the correction factors against the standard flow to size a refrigerated compressed air dryer.

Example
125 SCFM at 120°F inlet temperature, 125 PSIG and 110°F ambient.
125 * 1.3 * .98 * 1.1 = 175.1 SCFM
Model RD-220

Inlet Temperature Correction Factors
90°F 100°F 110°F 120°F 140°F 160°F
.85 1 1.15 1.3 1.7 1.9

Working Pressure Correction Factor
50 PSIG 75 PSIG 90 PSIG 100 PSIG 110 PSIG 125 PSIG 150 PSIG
1.25 1.11 1.05 1 .99 .98 .95

Ambient Temperature Correction Factor
90°F 100°F 110°F
.95 1 1.1

Filter Assembly Recommendations

Click on the filter assembly part number for pricing and full specifications. There is a drawing below the recommendation table that shows where in the system the filters should be installed. RD Series dryers should have atleast a 1 um coalescer upstream of them to remove bulk liquid and oil.

Model   Pre-Filter After-Filter
RD-10 MAC-15-1/4-GC
1 um Coalescer
MAC-15-1/4-HC
.01 um Coalescer
RD-20 MAC-25-1/2-GC
1 um Coalescer
MAC-25-1/2-HC
.01 um Coalescer
RD-30 MAC-55-1/2-GC
1 um Coalescer
MAC-55-1/2-HC
.01 um Coalescer
RD-40
RD-60
RD-80 MAC-85-3/4-GC
1 um Coalescer
MAC-85-3/4-HC
.01 um Coalescer
RD-100 MAC-100-1-GC
1 um Coalescer
MAC-100-1-HC
.01 um Coalescer
RD-130 MAC-150-1-GC
1 um Coalescer
MAC-150-1-HC
.01 um Coalescer
RD-150
RD-220 MAC-265-1-1/4-GC
1 um Coalescer
MAC-265-1-1/4-HC
.01 um Coalescer
RD-250
RD-330 MAC-350-1-1/2-GC
1 um Coalescer
MAC-350-1-1/2-HC
.01 um Coalescer
RD-400 MAC-400-2-GC
1 um Coalescer
MAC-400-2-HC
.01 um Coalescer
RD-500 MAC-500-2-GC
1 um Coalescer
MAC-500-2-HC
.01 um Coalescer

Refrigerated Compressed Air Filter Set-up

Sizing Tool

Select your inlet air temperature, PSIG, maximum ambient temperature, and enter your SCFM to and click "Size It" to get a refrigetated dryer recommendation.


SCFM: 
 

Sizing Results

Message:
Van Air Dryer Model:    
Click GO for Dryer Specs and Pricing.


Better Business Bureau Reliability Program Seal
eCompressedair Online Ordering uses Rapid SSL to ensure security
eCompressedair is a Safe Shopping Network Member. Click for Scoring.

 
Home |  Contact Us |  Shipping |  Payment Options |  Privacy |  Credit Application |  Store |  RFQ
Returns |  Products |  Site Map |  Links |  Library |  Line Card |  Trademark & Copyright Notice |  Industrial Distribution Resources